Featured
-
Factory wholesale medical titanium alloy material - Titanium alloy Gr5 plate for medical equipment – Xinnuo
Features Material Gr 5, Gr 5 ELI, Ti-6Al-4V ELI Standard ASTM F136, IS05832-3 Size (1.0~12.0) T * (300~1000) W * (1000~2000 )L mm Tolerance 0.05-0.2mm State M, Annealed Surface Condition Polished, Customized surface Roughness Ra<3.2 um Product Inspection Details as following 100% Surface defect detection . This part of the inspection surface is the first process in the inspection department. The bar is constantly rotated to check if there are any defects such a... -
Manufacturing Companies for Titanium Plate - Titanium alloy Gr5 plate for medical equipment – Xinnuo
Features Material Gr 5, Gr 5 ELI, Ti-6Al-4V ELI Standard ASTM F136, IS05832-3 Size (1.0~12.0) T * (300~1000) W * (1000~2000 )L mm Tolerance 0.05-0.2mm State M, Annealed Surface Condition Polished, Customized surface Roughness Ra<3.2 um Product Inspection Details as following 100% Surface defect detection . This part of the inspection surface is the first process in the inspection department. The bar is constantly rotated to check if there are any defects such a... -
Original Factory UNS R50700 Titanium bar - ASTM F67 Titanium round bar for Dental – Xinnuo
Specifications Chemical composition(%) Grade Ti Fe, max C, max N, max H, max O, max Gr3 Balance 0.30 0.08 0.05 0.015 0.35 Gr4 Balance 0.50 0.08 0.05 0.015 0.40 Mechanical properties Grade Condition Tensile Strength (Rm/Mpa) >= Yield Strength (Rp0.2/Mpa) >= Elongation (A%) >= Reduction of Area (Z%) >= Gr3 Annealed 450 380 18 30 Gr4 550 483 15 25 Quality control Are we a... -
Super Lowest Price DIN 3.7165 Titanium bar - ASTM F136 Ti-6Al-4V ELI Titanium Bar / Rod – Xinnuo
Specifications Chemical compositions Grade Ti Al V Fe, max C, max N, max H, max O, max Ti-6Al-4V EL Bal 5.5~6.5 3.5~4.5 0.25 0.08 0.05 0.012 0.13 Mechanical properties Grade Diameter (mm) Tensile Strength (Rm/Mpa) ≥ Yield Strength (Rp0.2/Mpa) ≥ Elongation (A%) ≥ Reduction of Area (Z%) ≥ Ti-6Al-4V ELI <44.45 860 795 10 25 Ti-6Al-4V ELI 44.45-63.5 825 760 8 20 Ti-6Al-4V ELI 63.5-101.6 825 ... -
Low MOQ for Femur Bone Plate - Titanium plate Gr1-Gr4 for surgical instrument – Xinnuo
Features Gr1, Gr2,Gr3 and Gr4 titanium plate for surgical instrument Material Gr1, Gr2,Gr3 and Gr4 Standard ASTM F67, IS05832-2 Regular Size (0.6~8) T * (300~400) W * (1000~1200 )L mm or customized size Thickness tolerance 0.05-0.3 mm State M, Annealed Surface Condition Acid washing, Polished we offered Test With mill test certificate, accept the third party test. Specification Chemical composition: Grade Ti Chemical composition (%) Impurity(%) Max... -
Low price for Titanium Bar Rod - Titanium bar for bone screw – Xinnuo
Characteristics 1. The physical properties of materials are controllable and customized. 2. The low and high microstructure of the material can be controlled and customized. 3. Suitable for cortical bone screws, cancellous bone screws, locking screws, medical titanium rods. We can do your high performance customized products in order to meet your requirement of better torque and high-torsion angle. Quality Inspection 1. Ultrasonic and eddy current testing make sure the produ... -
Hot Sale for Gr 3 Titanium Plate For Internal Bone Fixation - Titanium alloy Gr5 plate for medical equipment – Xinnuo
Features Material Gr 5, Gr 5 ELI, Ti-6Al-4V ELI Standard ASTM F136, IS05832-3 Size (1.0~12.0) T * (300~1000) W * (1000~2000 )L mm Tolerance 0.05-0.2mm State M, Annealed Surface Condition Polished, Customized surface Roughness Ra<3.2 um Product Inspection Details as following 100% Surface defect detection . This part of the inspection surface is the first process in the inspection department. The bar is constantly rotated to check if there are any defects such a... -
Short Lead Time for Thk 0.125inch(3.175mm) Titanium sheet - Titanium sheet applied for surgical bone locking system – Xinnuo
Common Specifications and Grades we offered. Material Gr.3, Gr.3, Gr.5, Ti-6Al-4V ELI, Ti6Al7Nb Standard ASTM F67, ASTM F136, ASTM F1295, IS05832-2, ISO 5832-3,ISO 5832-11 Regular Size (1.0~6.5) T * (300~400) W * (1000~1200 )L mm Thickness tolerance +0.1 mm for (1.0~3.0) T * (300~400) W * (1000~1200)L mm +0.2 mm for (3.0~6.5) T * (300~400) W * (1000~1200)L mm State M, Annealed Surface Condition Polishing, Acid washing Roughness Ra<3.2um ... -
High Quality Locking Plate Instrument Set - Pure and alloy titanium plate for internal bone fixation – Xinnuo
Features Material Gr3, Gr4, Gr5 ELI (Ti-6Al-4V ELI) Standard ASTM F67, ASTM F136, ISO 5832-2 , IS05832-3 Size δ (0.6~6.5) * (300~400) * (1000~1200 ) mm Thickness tolerance +0.1 mm for δ (1.0~3.0) * (300~400) * (1000~1200 ) mm +0.2 mm for δ (3.0~6.5) * (300~400) * (1000~1200 ) mm State M, Annealed Surface Polished, Acid-pickling Test With mill test certificate, accept the third party test. Chemical composition Grade Ti Chemical composition Major com... -
China Supplier ASTM F67 Titanium - Pure titanium plate for medical skull application – Xinnuo
Specifications Material Gr1, Gr2 Standard ASTM F67, IS05832-2 Regular Size 0.6-1.0 T * (280~350) W * (1000~2000 )L mm Thickness tolerance 0.05-0.1 mm State M (Annealed) Surface Cold-rolled surface Roughness Ra<0.08um Chemical composition: Grade Ti Chemical composition Impurity(=<%) Residual elements Fe C N H O Single Total Gr1 Bal 0.20 0.08 0.03 0.015 0.18 0.10 0.40 Gr2 Bal 0.... -
China Factory for ISO 5832-3 Titanium sheet - Pure and alloy titanium plate for internal bone fixation – Xinnuo
Features Material Gr3, Gr4, Gr5 ELI (Ti-6Al-4V ELI) Standard ASTM F67, ASTM F136, ISO 5832-2 , IS05832-3 Size δ (0.6~6.5) * (300~400) * (1000~1200 ) mm Thickness tolerance +0.1 mm for δ (1.0~3.0) * (300~400) * (1000~1200 ) mm +0.2 mm for δ (3.0~6.5) * (300~400) * (1000~1200 ) mm State M, Annealed Surface Polished, Acid-pickling Test With mill test certificate, accept the third party test. Chemical composition Grade Ti Chemical composition Major com... -
Factory wholesale medical titanium alloy material - Titanium alloy Gr5 plate for medical equipment – Xinnuo
Features Material Gr 5, Gr 5 ELI, Ti-6Al-4V ELI Standard ASTM F136, IS05832-3 Size (1.0~12.0) T * (300~1000) W * (1000~2000 )L mm Tolerance 0.05-0.2mm State M, Annealed Surface Condition Polished, Customized surface Roughness Ra<3.2 um Product Inspection Details as following 100% Surface defect detection . This part of the inspection surface is the first process in the inspection department. The bar is constantly rotated to check if there are any defects such a...