Featured
-
Big discounting Gr1 titanium plate - Titanium alloy Gr5 plate for medical equipment – Xinnuo
Features Material Gr 5, Gr 5 ELI, Ti-6Al-4V ELI Standard ASTM F136, IS05832-3 Size (1.0~12.0) T * (300~1000) W * (1000~2000 )L mm Tolerance 0.05-0.2mm State M, Annealed Surface Condition Polished, Customized surface Roughness Ra<3.2 um Product Inspection Details as following 100% Surface defect detection . This part of the inspection surface is the first process in the inspection department. The bar is constantly rotated to check if there are any defects such a... -
Lowest Price for Gr 4 Titanium Bar For Dental Implants - ASTM F67 Titanium round bar for Dental – Xinnuo
Specifications Chemical composition(%) Grade Ti Fe, max C, max N, max H, max O, max Gr3 Balance 0.30 0.08 0.05 0.015 0.35 Gr4 Balance 0.50 0.08 0.05 0.015 0.40 Mechanical properties Grade Condition Tensile Strength (Rm/Mpa) >= Yield Strength (Rp0.2/Mpa) >= Elongation (A%) >= Reduction of Area (Z%) >= Gr3 Annealed 450 380 18 30 Gr4 550 483 15 25 Quality control Are we a... -
Best-Selling ISO 5832-2 Titanium bar - ASTM F136 Ti-6Al-4V ELI Titanium Bar / Rod – Xinnuo
Specifications Chemical compositions Grade Ti Al V Fe, max C, max N, max H, max O, max Ti-6Al-4V EL Bal 5.5~6.5 3.5~4.5 0.25 0.08 0.05 0.012 0.13 Mechanical properties Grade Diameter (mm) Tensile Strength (Rm/Mpa) ≥ Yield Strength (Rp0.2/Mpa) ≥ Elongation (A%) ≥ Reduction of Area (Z%) ≥ Ti-6Al-4V ELI <44.45 860 795 10 25 Ti-6Al-4V ELI 44.45-63.5 825 760 8 20 Ti-6Al-4V ELI 63.5-101.6 825 ... -
OEM/ODM Supplier High strength Titanium wire - High Strength Medical Titanium Wire for Medical Kirschner wire – Xinnuo
High Strength Medical Titanium Wire 1.Brief introduction Grade Gr5, Ti-6Al-4V ELI Standard ISO5832-3, ASTM F136 Diameter 1-4mm Tensile strength >1080MPa Shape Straight wire Characteristic Surface roughness≤0.8µm Application Kirschner wire, elastic intramedullary nail Certificates Test report, Third party test report 2.Chemical compositions Grade Ti Chemical composition Major composition Impurity(=<%) Al V Fe C N H O Ti-6Al-4V ELI Bal 5.5-6.5 3.5-4.5 0.2... -
Lowest Price for Gr 4 Titanium Bar For Dental Implants - Titanium bar for hip joint – Xinnuo
Description of Titanium bar for hip joint Standard: ASTM F67, ISO5832-2, ASTM F136, ISO5832-3. Grade: Gr3, Gr5, Ti6Al4V, Ti6Al4V ELI Most ordered Diameter(mm): Φ16, Φ17.2, Φ18, Φ20, Φ24, Φ30, Φ40, Φ45, Φ50, Φ55, Φ65mm Characteristic: Good elasticity, high strength, good metallographic structure, good abrasion resistance. 1. For Gr3, microstructure can reach over level 7, tensile strength can reach more than 585MPa. 2. For Gr5, Gr5ELI, microstructure can reach A3, tensile strength can rea... -
Excellent quality Titanium wire for ISO5832-11 - High Strength Medical Titanium Wire for Medical Kirschner wire – Xinnuo
High Strength Medical Titanium Wire 1.Brief introduction Grade Gr5, Ti-6Al-4V ELI Standard ISO5832-3, ASTM F136 Diameter 1-4mm Tensile strength >1080MPa Shape Straight wire Characteristic Surface roughness≤0.8µm Application Kirschner wire, elastic intramedullary nail Certificates Test report, Third party test report 2.Chemical compositions Grade Ti Chemical composition Major composition Impurity(=<%) Al V Fe C N H O Ti-6Al-4V ELI Bal 5.5-6.5 3.5-4.5 0.2... -
OEM Factory for medical titanium wire - High Strength Medical Titanium Wire for Medical Kirschner wire – Xinnuo
High Strength Medical Titanium Wire 1.Brief introduction Grade Gr5, Ti-6Al-4V ELI Standard ISO5832-3, ASTM F136 Diameter 1-4mm Tensile strength >1080MPa Shape Straight wire Characteristic Surface roughness≤0.8µm Application Kirschner wire, elastic intramedullary nail Certificates Test report, Third party test report 2.Chemical compositions Grade Ti Chemical composition Major composition Impurity(=<%) Al V Fe C N H O Ti-6Al-4V ELI Bal 5.5-6.5 3.5-4.5 0.2... -
100% Original industrial titanium wire - High Strength Medical Titanium Wire for Medical Kirschner wire – Xinnuo
High Strength Medical Titanium Wire 1.Brief introduction Grade Gr5, Ti-6Al-4V ELI Standard ISO5832-3, ASTM F136 Diameter 1-4mm Tensile strength >1080MPa Shape Straight wire Characteristic Surface roughness≤0.8µm Application Kirschner wire, elastic intramedullary nail Certificates Test report, Third party test report 2.Chemical compositions Grade Ti Chemical composition Major composition Impurity(=<%) Al V Fe C N H O Ti-6Al-4V ELI Bal 5.5-6.5 3.5-4.5 0.2... -
China Gold Supplier for ISO 5832-3 Titanium Rod - Pure and alloy titanium plate for internal bone fixation – Xinnuo
Features Material Gr3, Gr4, Gr5 ELI (Ti-6Al-4V ELI) Standard ASTM F67, ASTM F136, ISO 5832-2 , IS05832-3 Size δ (0.6~6.5) * (300~400) * (1000~1200 ) mm Thickness tolerance +0.1 mm for δ (1.0~3.0) * (300~400) * (1000~1200 ) mm +0.2 mm for δ (3.0~6.5) * (300~400) * (1000~1200 ) mm State M, Annealed Surface Polished, Acid-pickling Test With mill test certificate, accept the third party test. Chemical composition Grade Ti Chemical composition Major com... -
Best quality Titanium Metal Rod - Ti6Al7Nb Titanium plate titanium alloys for orthopaedic implant – Xinnuo
Common Specifications and Grades we offered. Material Ti-6Al-7Nb Standard ASTM F1295, IS05832-11 Size δ (1.0~12.0) * (300~400) * (1000~1200 ) mm Tolerance 0.08-1.0mm State M, Annealed Surface Polishing, Pickled Mechanical Performance High precision Thickness tolerance 0.04-0.15mm, straightness within 1mm/m, surface smoothness is Ra<0.16um; High property Tensile strength can reach above 1000MPa; Microstructure A1-A6; NDT (nondestructive testing) Withi... -
Manufacturer of Titanium Sheet - Pure titanium plate for medical skull application – Xinnuo
Specifications Material Gr1, Gr2 Standard ASTM F67, IS05832-2 Regular Size 0.6-1.0 T * (280~350) W * (1000~2000 )L mm Thickness tolerance 0.05-0.1 mm State M (Annealed) Surface Cold-rolled surface Roughness Ra<0.08um Chemical composition: Grade Ti Chemical composition Impurity(=<%) Residual elements Fe C N H O Single Total Gr1 Bal 0.20 0.08 0.03 0.015 0.18 0.10 0.40 Gr2 Bal 0.... -
Free sample for Titanium Bar For Hip Joint - ASTM F67 Titanium Bar / Rod – Xinnuo
Description of ASTM F67 Titanium Bar (Rod) Material grade Gr1, Gr2, Gr3, Gr4 (pure titanium ) Standard ASTM F67, ISO 5832-2 Surface Polishing Size Diameter 3mm – 120mm, length:2500-3000mm or customized Tolerance h7/ h8/ h9 for diameter 3-20mm Specifications Chemical composition Grade Ti Fe, max C, max N, max H, max O, max Gr1 Bal 0.20 0.08 0.03 0.015 0.18 Gr2 Bal 0.30 0.08 0.03 0.015 0.25 ...